LODD Anniversary: Battalion Chief, Firefighter Killed, 29 Firefighters Injured in Pennsylvania Church Fire

Fire breaking through roof of incident structure. (NIOSH photo)

Collapse kills two after church fire in 2004

Fire breaking through roof of incident structure. (NIOSH photo)

NIOSH Fire Fighter Fatality Investigation and Prevention Program

On March 13, 2004, a 55-year-old male career Battalion Chief (Victim #1) and a 51-year-old male career master fire fighter (Victim #2) were fatally injured during a structural collapse at a church fire.

Read the Report:
Career Battalion Chief and Career Master Fire Fighter Die and Twenty-Nine Career Fire Fighters are Injured during a Five Alarm Church Fire

Victim #1 was acting as the Incident Safety Officer and Victim #2 was performing overhaul, extinguishing remaining hot spots inside the church vestibule when the bell tower collapsed on them and numerous other fire fighters.

Twenty-three fire fighters injured during the collapse were transported to area hospitals.

A backdraft occurred earlier in the incident that injured an additional six fire fighters.

The collapse victims were extricated from the church vestibule several hours after the collapse. The victims were pronounced dead at the scene.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:

  • ensure that an assessment of the stability and safety of the structure is conducted before entering fire and water-damaged structures for overhaul operations
  • establish and monitor a collapse zone to ensure that no activities take place within this area during overhaul operations
  • ensure that the Incident Commander establishes the command post outside of the collapse zone
  • train fire fighters to recognize conditions that forewarn of a backdraft
    ensure consistent use of personal alert safety system (PASS) devices during overhaul operations
  • ensure that pre-incident planning is performed on structures containing unique features such as bell towers
  • ensure that Incident Commanders conduct a risk-versus-gain analysis prior to committing fire fighters to an interior operation, and continue to assess risk-versus-gain throughout the operation including overhaul
  • develop standard operating guidelines (SOGs) to assign additional safety officers during complex incidents
  • provide interior attack crews with thermal imaging cameras

Additionally,

  • municipalities should enforce current building codes to improve the safety of occupants and fire fighters

special needs tour Decatur (AL)

Special Needs Adults Thrilled by Decatur (AL) Fire Station Tour

Firefighters turned on the emergency lights, which brought up bars of flashing red lights that danced off the sides of the garage, entertaining the group…
Goodview (MN) Fire Chief Jason Gruett

Goodview (MN) Fire Department Mourns the Loss of Chief Jason Gruett

Goodview Fire Chief Jason Gruett unexpectedly passed away at 51 years old on March 12, leaving a major loss within the fire department.