NIOSH Firefighter Fatality Investigation: New York Firefighter Dies during Confined Space Rescue

The NIOSH Firefighter Fatality Investigation and Prevention Program has released the line of duty death report of a New York volunteer firefighter killed while attempting to rescue a utility worker from a confined space in September 2010.

Read the Report
Volunteer Firefighter Dies During Attempted Rescue of Utility Worker


On September 6, 2010, a 51-year-old male volunteer fire fighter (victim) died after being overcome by low oxygen and sewer gases while climbing down into a sewer manhole in an attempt to rescue a village utility worker. The utility worker had entered the manhole to investigate a reported sewer problem and was overcome by low oxygen and sewer gases (see diagram 1). The incident occurred behind the fire station in an underground sewer line that ran under the fire station. The local utility company contacted the chief of the village’s volunteer fire department and requested that a piece of fire apparatus be moved out of the station so they would not block it in while accessing a manhole. The fire chief responded to the station to move fire apparatus so it would not be blocked by the utility trucks. The victim and another fire fighter also arrived at the station to assist.

A utility worker entered the manhole behind the station to clear a sewer backup and was overcome by a lack of oxygen and sewer gases and then fell unconscious inside the manhole. The victim then entered the manhole without any personal protective equipment to help the utility worker and was also overcome by the low oxygen level and sewer gases.

The victim and the utility worker were later removed from the sewer manhole by fire department personnel and transported to a local hospital where they were pronounced dead. The medical examiner reported the cause of death as asphyxia due to low oxygen and exposure to sewer gases.

Contributing Factors:

  • Unrecognized hazards involved with a confined space
  • Lack of Standard Operating Procedures (SOP’s) for confined space technical rescue operations
  • In-effective incident management system for a confined space technical rescue operation.

Key Recommendations:

  • Ensure that fire fighters are properly trained and equipped to recognize the hazards of and participate in a confined space technical rescue operation
  • Ensure that standard operating procedures regarding technical rescue capabilities are in place and a risk benefit analysis is performed to protect the safety of all responders
  • Ensure that an effective incident management system is in place that supports technical rescue confined space operations
  • Ensure that a safety officer properly trained in the technical rescue field being performed is on scene and integrated into the command structure.

 

Twin Falls (ID) Chief Retires

Twin Falls (ID) Fire Chief Retires After 7 Years

At the end, Kenworthy received the traditional “final call” from a dispatcher, and after the crowd enjoyed refreshments, was given a ride home in a…
Cal Fire Captain Rebecca Marodi

Mexican Officials Arrest Suspect in Stabbing Death of Cal Fire Captain

Authorities in Mexico on Saturday arrested the woman suspected in the alleged stabbing death of a Cal Fire captain killed in her Ramona home, culminating a five-week, bi-national manhunt.