Firefighter Nation

Firefighting & Rescue Social / Professional Network

February is American Heart Month.

That’s it; one month and the shortest one at that?

How can we expect to maintain a sustained effort to reduce heart-related deaths in the fire service if we only pull out the PR campaign once a year?

Besides; we will forget about it as quickly as we forget all of those New Years’ resolutions. You know the ones; going to lose weight, eat healthier, exercise more and trim your nose hair more often.

Doing what I just mentioned is taking some personal responsibility in our battle to reduce LODD heart attacks, but what about some of the triggers that come from outside the body; something like hydrogen cyanide (HCN)?

You should know that HCN is peeking over the shoulder of carbon monoxide (CO) at your structural fires.

Think about it; how many times have you read a post-mortem on a firefighter that says, “Recent physical found patient to be in good condition; no family history of heart disease; death from sudden cardiac arrest”?

If I was a betting man and I am, I would bet that hydrogen cyanide (HCN) got to him while he was inside doing salvage and over-haul and at a time when many of you will shed your SCBAs.

Why would we suspect hydrogen cyanide (HCN)?

For one thing, it’s a sneaky bastard.

It is colorless; it doesn’t always give off an odor and is released when products such as wool, silk, cotton, nylon, plastic, polymers, foam, melamine, polyacrylonitriles and synthetic rubber burns.

So, that “smoke” that you smell most likely contains hydrogen cyanide (HCN).

Plus, hydrogen cyanide (HCN) likes to hang out in enclosed areas. It dissipates very quickly outdoors, but inside, it is less dense than air and will rise, but will remain trapped in rooms.

As you breathe it, it will prevent the cells in the body from using oxygen, killing the cells. Since our heart and our brain use more oxygen than the other organs, they will be more greatly affected. It could cause the brain to become confused and send mixed signals to the heart, causing arrhythmia.

Other signs and symptoms of HCN exposure that should not be ignored are rapid breathing, restlessness, dizziness, weakness, headache, nausea/vomiting and rapid heart rate could give way to convulsions, low blood pressure, slow heart rate, loss of consciousness, lung injury and respiratory failure leading to death.

And were it not for the fact that you are a firefighter, these symptoms might be explained by some other medical reasoning.

And let’s be honest; some of the symptoms that I have described have been experienced by many of us at a fire scene, but ignored, because we figured it was from adrenaline, possibly smokeless tobacco or physical exertion. THAT is why we need to go to rehab and THEY have to be familiar with HCN exposure.

If you don’t think that this gas-a gas that is 35 times more toxic than carbon monoxide (CO)-can kill you, then why was it used in Nazi death camps during World War II?

Yeah; I know THAT got your attention!

Here is the most insidious characteristic of hydrogen cyanide (HCN): you may not suffer any short term effects at the time of exposure, but may develop symptoms after two or three weeks. This leads to the LODD question and the linkage to death due quite possibly to HCN exposure and whether it qualifies.

How many of you have gas detectors that test for hydrogen cyanide (HCN)?

How many of you wear full turnout gear, including SCBAs during ALL interior operations and until they are concluded? Dumpster fires? Vehicle fires? You’d better think about it.

How many departments have a rehab unit that is trained in HCN exposure recognition?

The Centers for Disease Control and Prevention has several articles on hydrogen cyanide (HCN) that are worth your time to read.

One of the best articles out there right now is an article by Richard Rochford entitled “Hydrogen Cyanide: New Concerns for Firefighting”. It is a must read.

Then, click on www.firesmoke.org. Shawn Longerich would love to hear from you.

By recognizing and respecting the dangers of hydrogen cyanide, we may save more lives, including our own.

Being a “smoke eater” is no longer a badge of honor.

TCSS.

Sources:

Hydrogen Cyanide: New Concerns for Firefighting by Richard Rochford

Facts About Cyanide – Centers for Disease Control and Prevention

February is American Heart Month – Centers for Disease Control and Prevention

The article is protected by federal copyright law under The Adventures of Jake and Vinnie© umbrella. It is written and submitted by Art Goodrich a.k.a. ChiefReason. This article or any other article submitted under The Adventures of Jake and Vinnie© umbrella cannot be reproduced in ANY form without the expressed, written permission of the author. Violations are punishable by applicable laws.
Please visit: www.chiefreasonart.com

Tags: attacks, chief, cyanide, heart, hydrogen, lodd, longerich, reason, richard, rochford

Add a Comment

You need to be a member of Firefighter Nation to add comments!

Join Firefighter Nation

Capt 723 Comment by Capt 723 on February 4, 2010 at 9:23am
This needs to be read and everyone's next training session and then hung up on the wall for everyone to see.
Art "ChiefReason" Goodrich Comment by Art "ChiefReason" Goodrich on February 4, 2010 at 8:52am
Brooksy:
I would get a little nervous if someone mentioned that someone was roasting almonds nearby.
I have read that, if HCN gives off an odor, it smells like "roasted almonds".
I believe it is the law that an IDLH atmosphere MUST be tested before entry.
No?
Jason Brooks Comment by Jason Brooks on February 4, 2010 at 8:29am
This only further emphasizes that we need to be more diligent in metering during overhaul. There is not excuse for being in a situation without making sure it is safe to remove SCBA. Every fire department has at least a 3 gas meter, if not they need to get one yesterday. There are single gas HCN meters that can be clipped to your coat and be worn during overhaul as well. It should be negligent if we do not monitor for potentially dangerous gases. Just because there is no smoke, does not make the space clean.
Jason Hoevelmann (aka FFsEnemy) Comment by Jason Hoevelmann (aka FFsEnemy) on February 3, 2010 at 11:13pm
Well said and thanks for bringing this up again. I have read some stuff that agrees with what you are saying. Like everything else, it will likely take a while for "us" to change how we do things to keep "us" healthy.
eMail Alerts
Get hot content from FFN and FireRescue
FireRescue eNews
Breaking & Daily News
Special Promos
Webcast/Events
*Your eMail Address:

© 2010   An Elsevier Public Safety & Go Forward Media, LLC Product -   Partners: JEMS Connect - FireRescue - JEMS
Contact Us: Report an Issue, Inquire About Advertising & Partnerships - View Our Media Kit
This site is intended for use by current and former fire, rescue & EMS professionals. Non emergency service personnel may be subject to review and removal. Using this site inappropriately to spam/advertise or solicit members in any way will result in account termination. Commercial companies may have profiles, but blogs, groups, forums, videos and photos and any other area may not be used for self-promotion.

Badges  |  Contact Firefighter Nation  |  Terms of Service